Voltlim
Voltlim
  • Home
  • Product
    • Electricity Act Notice
    • SS 638 Warning Notice
    • SS 555 LPS Warning Sign
    • Electrical Label
    • EV Sign & Label
    • Fire Code Label & Sign
    • Code of Accessibility
    • Construction Site Sign
    • WSH Sign
  • Store
  • Contact Us
  • Electrical Design
    • Content
    • Chapter 1 Introduction
    • Chapter 2 Fundamental Req
  • More
    • Home
    • Product
      • Electricity Act Notice
      • SS 638 Warning Notice
      • SS 555 LPS Warning Sign
      • Electrical Label
      • EV Sign & Label
      • Fire Code Label & Sign
      • Code of Accessibility
      • Construction Site Sign
      • WSH Sign
    • Store
    • Contact Us
    • Electrical Design
      • Content
      • Chapter 1 Introduction
      • Chapter 2 Fundamental Req
  • Sign In
  • Create Account

  • My Account
  • Signed in as:

  • filler@godaddy.com


  • My Account
  • Sign out

Signed in as:

filler@godaddy.com

  • Home
  • Product
    • Electricity Act Notice
    • SS 638 Warning Notice
    • SS 555 LPS Warning Sign
    • Electrical Label
    • EV Sign & Label
    • Fire Code Label & Sign
    • Code of Accessibility
    • Construction Site Sign
    • WSH Sign
  • Store
  • Contact Us
  • Electrical Design
    • Content
    • Chapter 1 Introduction
    • Chapter 2 Fundamental Req

Account


  • My Account
  • Sign out


  • Sign In
  • My Account

Fire code label & signage 1

Manual Call Point Sign

 Fire Certificate Inspection Checklist requires "CASE OF FIRE CALL 995” signage for MANUAL ALARM SYSTEM (CALL POINT) 


To purchase these products go to our online store or https://shopee.sg/voltlim

In Case of Fire Call 995 sign

In Case of Fire Call 995 sign

Fire code label & signage 2

F001 Fire Extingusher Signage

Fire Extinguishers shall be conspicuously located in locations where they will be readily accessible and immediately available in the event of fire.

In certain locations where visual obstruction cannot be completely avoided, signs (see SS 508-3) shall be provided to indicate the location.


To purchase these products go to our online store or https://shopee.sg/voltlim

F001 Fire Extingusher Sign

F001 Fire Extingusher Sign

Fire code label & signage 3

F002 Fire Hose Reel Signage

 Graphical symbols to depict fire safety equipment are allowed for use in buildings provided the signs comply with SS 508. 


To purchase these products go to our online store or https://shopee.sg/voltlim

F002 Fire Hose Reel Sign

F002 Fire Hose Reel Sign

FIRE CODE LABEL & SIGNAGE

Fire Alarm System Label Sticker

 For fire protection systems pipework, conduits, trunkings and cable trays which are not required to be painted in red, red colour bands of width not less than 20mm and labelling shall be provided at an interval of not more than 6m apart. 


To purchase these products go to our online store or https://shopee.sg/voltlim

Fire Alarm System Label Sticker

Fire Alarm System Label Sticker

Fire code label & signage 4

F000 Fire Directional Arrow Signage

Graphical symbol of arrow to used with fire safety equipment symbols to point to the location of fire safety equipment.


To purchase these products go to our online store or https://shopee.sg/voltlim

F000 Fire Directional Arrow Sig

F000 Fire Directional Arrow Sign

Fire code label & signage 5

Fire Shutter Keep Clear Sign

 

Signage for alerting persons not to impede the operation of fire shutters shall be permanently displayed at prominent locations and suitable intervals close to the descending paths of the fire shutters. The lettering of the sign shall be at least 25mm high in a colour contrasting with the background and states the following where applicable:

(1) “FIRE SHUTTER – KEEP CLEAR”

To purchase these products go to our online store or https://shopee.sg/voltlim

Fire Shutter Keep Clear Floor Sticker 407mm x 90mm

Fire Shutter Keep Clear Floor Sticker 407mm x 90mm

Fire code label & signage 6

Smoke Curtain Keep Clear Sign

 

Signage for alerting persons not to impede the operation of smoke curtains shall be permanently displayed at prominent locations and suitable intervals close to the descending paths of the smoke curtains. The lettering of the sign shall be at least 25mm high in a colour contrasting with the background and states the following where applicable:

“SMOKE CURTAIN – KEEP CLEAR”

 

To purchase these products go to our online store or https://shopee.sg/voltlim

Smoke Curtain Keep Clear Floor Sticker 407mm x 90mm

Smoke Curtain Keep Clear Floor Sticker 407mm x 90mm

Fire code label & signage 7

Exit & Exit Directional Sign For Fire Shutter And Smoke Curtain

 

Exit directional signage marked with an arrow and the word “EXIT” shall be prominently painted/ pasted on fire shutters/ smoke curtains to redirect building occupants to the nearest exits if the activated shutters visually obscure the building exit and/ or directional signs. The sign shall be reflective and the letters at least 100mm in height. 


 


To purchase these products go to our online store or https://shopee.sg/voltlim

Exit Directional signage for fire shutter and smoke curtain

Exit & Exit Directional Sign For Fire Shutter And Smoke Curtain

Fire code label & signage 8

Exit Only No Re-Entry To Building Doors with One-Way Lock

 

Where one-way locking devices or electromagnetic/ electromechanical locking devices are installed at the doors of exit staircases, a signage shall be provided to warn occupants that they would not be able to re-enter the floor should they exit from it. A readily visible sign with the lettering “EXIT ONLY, NO RE-ENTRY TO BUILDING” shall be positioned at the entrance into the exit staircase. This signage shall be applicable for all buildings except PG I & II. 


To purchase these products go to our online store or https://shopee.sg/voltlim

Exit Only No Re-Entry To Building Doors with One-Way Lock Sign

Fire code label & signage 9

Person with Disabilities (PWD) Holding Point Sign

 Where a PWD Holding Point is located, a mandatory sign worded “PWD Holding Point” shall be prominently displayed.


To purchase these products go to our online store or https://shopee.sg/voltlim

PWD Holding Point Keep Clear Sign

PWD Holding Point Keep Clear Sign

Fire code label & signage 10

Emergency main isolation shut-off switches Sign

  

Main isolation shut-off switches can be allowed to be less than 3m from an EV charging station and its parking lot(s), as long as there is at least one other main isolation shut-off switch located at least 3m away but still within 15m of this EV charging station and its parking lot(s).

Main isolation shut-off switches shall be located between 800mm and 1.2m above the finished floor level and shall be located in a clearly visible and easily accessible location.

All main isolation shut-off switches shall be clearly labelled. Clear instructions shall be indicated on how to operate the main isolation shut-off switch. Signages shall be provided with a letter height of at least 50mm.


Where main isolation shut-off switch(es) cannot be seen clearly or not within line of sight from the EV charging station and its parking lot(s), additional signages shall be provided to direct persons to the main isolation shut-off switch(es).

 


To purchase these products go to our online store or https://shopee.sg/voltlim

EV Chargers E-Stop Sign

EV Chargers E-Stop Sign

FIRE CODE LABEL & SIGNAGE 12

Petroleum Service Stations LPG Danger Sign

.(1) Warning signs shall be conspicuously displayed at the individual dispensing area incorporating the following wordings: “WARNING - NO SMOKING, NO NAKED LIGHTS, STOP ENGINE”. The lettering shall be at least 50mm high. 


 (2) The signs shall be displayed not less than 1.8m and not more than 2.5m above the ground level. 


Note: Label sticker in 420mm x 297mm does not meet the code requirement in 50mm lettering height. Sign with 50mm high needs special order.


To purchase these products go to our online store or https://shopee.sg/voltlim


Petroleum Service Stations LPG Danger Sign

Petroleum Service Stations LPG Danger Sign

Fire code label & signage 13

Petrol Station Warning Sign

Warning signs shall be conspicuously posted at the individual dispensing area incorporating the following wordings: "WARNING - NO SMOKING, NO NAKED LIGHTS, STOP ENGINE". The lettering shall be at least 50mm high.


The signs shall be posted not less than 1.8m and not more than 2.5m above the ground level.  


Note: Label sticker in 420mm x 297mm does not meet the code requirement in 50mm lettering height. Sign with 50mm high needs special order.



To purchase these products go to our online store or https://shopee.sg/voltlim

Petrol Station Warning Sign

Petrol Station Warning Sign

Copyright © 2024 Voltlim - All Rights Reserved.

Powered by Curiosity

This website uses cookies.

We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.

Accept