Fire Certificate Inspection Checklist requires "CASE OF FIRE CALL 995” signage for MANUAL ALARM SYSTEM (CALL POINT)
To purchase these products go to our online store or https://shopee.sg/voltlim
Fire Extinguishers shall be conspicuously located in locations where they will be readily accessible and immediately available in the event of fire.
In certain locations where visual obstruction cannot be completely avoided, signs (see SS 508-3) shall be provided to indicate the location.
To purchase these products go to our online store or https://shopee.sg/voltlim
Graphical symbols to depict fire safety equipment are allowed for use in buildings provided the signs comply with SS 508.
To purchase these products go to our online store or https://shopee.sg/voltlim
For fire protection systems pipework, conduits, trunkings and cable trays which are not required to be painted in red, red colour bands of width not less than 20mm and labelling shall be provided at an interval of not more than 6m apart.
To purchase these products go to our online store or https://shopee.sg/voltlim
Graphical symbol of arrow to used with fire safety equipment symbols to point to the location of fire safety equipment.
To purchase these products go to our online store or https://shopee.sg/voltlim
Signage for alerting persons not to impede the operation of fire shutters shall be permanently displayed at prominent locations and suitable intervals close to the descending paths of the fire shutters. The lettering of the sign shall be at least 25mm high in a colour contrasting with the background and states the following where applicable:
(1) “FIRE SHUTTER – KEEP CLEAR”
To purchase these products go to our online store or https://shopee.sg/voltlim
Signage for alerting persons not to impede the operation of smoke curtains shall be permanently displayed at prominent locations and suitable intervals close to the descending paths of the smoke curtains. The lettering of the sign shall be at least 25mm high in a colour contrasting with the background and states the following where applicable:
“SMOKE CURTAIN – KEEP CLEAR”
To purchase these products go to our online store or https://shopee.sg/voltlim
Exit directional signage marked with an arrow and the word “EXIT” shall be prominently painted/ pasted on fire shutters/ smoke curtains to redirect building occupants to the nearest exits if the activated shutters visually obscure the building exit and/ or directional signs. The sign shall be reflective and the letters at least 100mm in height.
To purchase these products go to our online store or https://shopee.sg/voltlim
Where one-way locking devices or electromagnetic/ electromechanical locking devices are installed at the doors of exit staircases, a signage shall be provided to warn occupants that they would not be able to re-enter the floor should they exit from it. A readily visible sign with the lettering “EXIT ONLY, NO RE-ENTRY TO BUILDING” shall be positioned at the entrance into the exit staircase. This signage shall be applicable for all buildings except PG I & II.
To purchase these products go to our online store or https://shopee.sg/voltlim
Where a PWD Holding Point is located, a mandatory sign worded “PWD Holding Point” shall be prominently displayed.
To purchase these products go to our online store or https://shopee.sg/voltlim
Main isolation shut-off switches can be allowed to be less than 3m from an EV charging station and its parking lot(s), as long as there is at least one other main isolation shut-off switch located at least 3m away but still within 15m of this EV charging station and its parking lot(s).
Main isolation shut-off switches shall be located between 800mm and 1.2m above the finished floor level and shall be located in a clearly visible and easily accessible location.
All main isolation shut-off switches shall be clearly labelled. Clear instructions shall be indicated on how to operate the main isolation shut-off switch. Signages shall be provided with a letter height of at least 50mm.
Where main isolation shut-off switch(es) cannot be seen clearly or not within line of sight from the EV charging station and its parking lot(s), additional signages shall be provided to direct persons to the main isolation shut-off switch(es).
To purchase these products go to our online store or https://shopee.sg/voltlim
.(1) Warning signs shall be conspicuously displayed at the individual dispensing area incorporating the following wordings: “WARNING - NO SMOKING, NO NAKED LIGHTS, STOP ENGINE”. The lettering shall be at least 50mm high.
(2) The signs shall be displayed not less than 1.8m and not more than 2.5m above the ground level.
Note: Label sticker in 420mm x 297mm does not meet the code requirement in 50mm lettering height. Sign with 50mm high needs special order.
To purchase these products go to our online store or https://shopee.sg/voltlim
Warning signs shall be conspicuously posted at the individual dispensing area incorporating the following wordings: "WARNING - NO SMOKING, NO NAKED LIGHTS, STOP ENGINE". The lettering shall be at least 50mm high.
The signs shall be posted not less than 1.8m and not more than 2.5m above the ground level.
Note: Label sticker in 420mm x 297mm does not meet the code requirement in 50mm lettering height. Sign with 50mm high needs special order.